Analog Port Ground Fault Out-of-Service Alarm

The alarm is applicable only to FXS interfaces for the following products: Mediant 500L, Mediant 800, and Mediant 1000.

acAnalogPortGroundFaultOutOfService

Alarm

acAnalogPortGroundFaultOutOfService

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.76

Default Severity

Major / Clear

Source Varbind Text

System#0/analogports#<n>, where n is the port number

Event Type

physicalViolation

Probable Cause

equipmentMalfunction (this alarm is sent when the FXS port is inactive due to a ground fault)

Alarm Text

Analog Port Ground Fault Out Of Service

Corrective Action

No corrective action is required.
The device shuts down the port and tries to activate it again when the relevant alarm is over.